Skip to content
Rektron

Search

    On-premise system

    Rektron SQC

    Rektron SQC gives quality work its own system inside your network: collect measurements, see whether the process is stable and capable, and show your customer what has been inspected.

    The value

    Fewer surprises in the process, and evidence that holds up

    The value lies in seeing deviations while there is still time to act, and in calculations that are done the same way every time.

    01

    See the change before it becomes scrap

    Control charts and trends per characteristic show how the process moves over time, so a drift is visible before parts fall outside the tolerance.

    02

    Know whether the process meets the requirements

    Capability indices such as Cp, Cpk, Pp, Ppk and Cm/Cmk are calculated for all or for filtered parts of the measurement results, with a choice of distribution.

    03

    Trust the measurement

    Measurement system analysis with Gage R&R and attribute studies shows how much of the variation comes from the measurement itself.

    The context

    Quality work close to production, in your own environment

    Rektron SQC supports the chain from preparation to report: articles and characteristics are prepared with nominal values and limits, measurement takes place at the station or in the measuring room, and the results are analysed and reported.

    The system is installed on-premise: Windows programs for the people who measure, prepare and analyse, and a Microsoft SQL Server database where all measurements are stored. It suits organisations that want measurement data and statistics inside their own network.

    Where in the work

    1. 01Design(not covered here)
    2. 02Preparation(supported)
    3. 03Measurement(supported)
    4. 04Analysis(supported)
    5. 05Reporting(supported)
    6. 06Production follow-up(not covered here)

    The problems

    Problems Rektron SQC helps with

    • Problem: The deviation is only found at final inspection.

      Consequence: Parts that have already been made have to be sorted, reworked or scrapped.

    • Problem: Measurements are spread across files, CMM software and binders.

      Consequence: It takes a long time to gather evidence when a customer asks or a complaint has to be investigated.

    • Problem: Nobody knows how much of the variation comes from the measurement system.

      Consequence: Decisions are made on values that may be more measurement noise than real process variation.

    • Problem: The customer requires documented capability.

      Consequence: Without calculated indices and history it is hard to show that the process meets the requirements.

    How it works

    From measuring station to report

    Measurements are collected in one place, in a database at your site, and then used for control, analysis and reports.

    How does measurement data move through Rektron SQC?

    The path of measurement data through Rektron SQCMeasurements are entered at the inspection station in Desktop Client, and result files from measuring machines are imported automatically by the CMM Autonomous server service. All values are stored in a Microsoft SQL Server database in your network. Control charts, capability indices and measurement system analyses are produced from the database. Reports are created in Rektron SQC Reports, and Reports Server can send scheduled reports by email.YOUR NETWORK · ON-PREMISE Inspection stationsand CMMsDesktop Client andCMM Autonomous SQL ServerdatabaseAll measurementsin one place SPC, capabilityand MSAControl charts,indices, Gage R&R ReportsReports andReports Server

    Everything runs in your own network: Windows programs for the people who measure and analyse, and a Microsoft SQL Server database where the measurements are stored.

    Step by step

    1. Measurements are entered at the inspection station in Desktop Client, and result files from measuring machines are imported automatically by the CMM Autonomous server service.
    2. All values are stored in a Microsoft SQL Server database in your network.
    3. Control charts, capability indices and measurement system analyses are produced from the database.
    4. Reports are created in Rektron SQC Reports, and Reports Server can send scheduled reports by email.
    1. 01

      Prepare articles and characteristics

      Nominal values, limits and SPC control parameters are set per characteristic, so every measurement is compared with the right requirement.

    2. 02

      Measure at the station, or let the CMM send the results

      Values are entered in Desktop Client at the inspection station. Result files from coordinate measuring machines and other equipment are imported automatically by the CMM Autonomous server service.

    3. 03

      Store everything in one database

      Measurements are stored in a Microsoft SQL Server database, with a cavity number per value where needed.

    4. 04

      Analyse

      Control charts and trends per characteristic, capability indices such as Cp, Cpk, Pp, Ppk, Cm/Cmk and Q according to ISO 3951 with confidence intervals, selection per cavity for comparison and MSA with Gage R&R.

    5. 05

      Report

      Reports are created in Rektron SQC Reports, and Reports Server can send scheduled reports by email.

    The parts

    The programs in Rektron SQC

    The system consists of a few programs and server services, each covering part of the work.

    Desktop programs

    Rektron SQC Desktop Client

    The everyday tool for operators, measurement technicians and preparers: measurement, preparation and analysis.

    Rektron SQC Menu

    Starts Desktop Client for the right measurement application or department and configures the data sources against the database.

    Rektron SQC Administration

    Management of custom data fields, archiving of measurement data and software licences.

    Rektron SQC Reports

    Report generator where users choose the data selection and grouping.

    Server services

    Rektron SQC CMM Autonomous

    Imports result files from coordinate measuring machines and other equipment automatically, in the background.

    Rektron SQC Reports Server

    Creates reports on a schedule and sends them by email.

    Rektron SQC Database

    The database where all measurements are stored, on a Microsoft SQL Server instance.

    Edition for regulated environments

    Rektron SQC Audit Trail

    An edition with support for FDA 21 CFR Part 11, with access control and an audit trail.

    Facts

    Versions

    Which versions exist and what changed in each one.

    See the version history

    Support

    Rektron SQC is maintained and supported by Rektron.

    Contact support

    Who it is for

    For the people who measure, prepare and own quality

    • Operators

      Enter measurements at the station and see immediately whether the value is within the limits.

    • Quality

      Follow the stability and capability of the process and prepare evidence for customers and audits.

    • Measurement technicians and preparers

      Prepare articles and characteristics, set up imports from measuring machines and run measurement system analyses.

    • IT

      Run the programs and the SQL Server database in your own network.

    The benefit

    Why it is useful in daily work

    • Measurement data, statistics and reports are in one system, in your own environment.
    • Calculations are done the same way every time, instead of in individual spreadsheets.
    • Automatic import from measuring machines reduces manual transfer of values.
    • Measurements can be compared per cavity, for example in injection moulding with multi-cavity tools.
    • Reports can be sent automatically to the people who need them.

    The bigger picture

    How Rektron SQC relates to Eyesight

    Rektron SQC is maintained and supported. New development at Rektron happens in Eyesight, the cloud platform for quality control and production follow-up.

    Some of what SQC does is also available in Eyesight, for example Cp and Cpk per characteristic and measurement system analysis with Gage R&R. In-depth capability studies with more indices, such as Pp/Ppk, CpXR, CpXS and Q according to ISO 3951, are in Rektron SQC.

    If you are considering how to use SQC and Eyesight going forward, we review the functions you use today and suggest a set-up that suits you.

    Next step

    Want to know whether Rektron SQC suits you?

    Tell us how you measure and analyse today. We will go through what SQC does, and whether Eyesight is a better fit for what you want to achieve.